ferroelectronic.blogg.se

Dell b2360dn firmware update 6.
Dell b2360dn firmware update 6.




dell b2360dn firmware update 6.
  1. DELL B2360DN FIRMWARE UPDATE 6. SERIAL
  2. DELL B2360DN FIRMWARE UPDATE 6. DOWNLOAD
  3. DELL B2360DN FIRMWARE UPDATE 6. FREE

Also, if you connected immediately back in via SSH, or were using a serial connection - after your ping to the group IP started to drop, you can wait around in the CLI until the restart firmware complete notification echo's in the CLI. If that's the case for you, just wait a few minutes and refresh the info. If you happen to be a bit impatient and login to the Web interface too soon and check the firmware, you might notice an error like "battery failed" on whichever controller was second to restart (even if the firmware revision is not updated). Dell Nautilus Firmware Update Utility A19 for SAS and SATA disk and solid state drives: : Nautilus SAS-SATA EFI A19ZPE.exe: Urgent: A19: A19: normal: Dell Nautilus Firmware Update Utility A19 for SAS and SATA disk and solid state drives: : SAS-DriveFirmwareRHYJYLNVT33A00. If you have vCenter open, you might notice that very briefly (less than 10 seconds in my case) some of the VM's and/or datastores will read as "unavailable".

  • After the second controller is restarted, go ahead an login into the Web UI (or the CLI if that's your preference) and check that the PS has been successfully upgraded by looking at the controller tab and verifying that the firmware was upgraded to version you expect.
  • that point depending on which IP and controller you connected to earlier. Also realize that your SSH session will drop at some point. The Group IP will stop responding during the update of the second controller restart, in my case there were 6 dropped packets during in a continuous ping to the Group IP. keep in mind, this restart effects the controllers 1 at a time.
  • Use the "restart" command when finished.
  • I had shut all of my VM's down (expect 1), so there wasn't much I/O going on at the time. It took about 4 minutes per controller for me.
  • Use the "update" command, and the firmware will validate and begin updating the controllers - 1 at a time.
  • dell b2360dn firmware update 6.

    SSH into the PS using grpadmin credentials - connect to one of the individual ports, not the group IP.

    DELL B2360DN FIRMWARE UPDATE 6. FREE

    So if you get a failure notification about not having enough free space, it's probably talking about the FTP site - check and see what all you have in there.

  • If you have old *.tgz's in there, you can delete them to clear up space.
  • FTP into the PS using your grpadmin credentials and upload the tgz file to the root of the FTP site.
  • If you get the zip, extract it because the PS6000xv just wants the *.tgz

    DELL B2360DN FIRMWARE UPDATE 6. DOWNLOAD

    Download the firmware 4.3.6 from the Equallogics support site using your individual credentials.For instance, if you have servers mounting LUNs directly off of the PS, they too will create I/O. While your thinking about that statement, make sure you factor in any I/O that's happening outside of your virtualization stack. Depending on what firmware you're at, you don't need to have your I/O completely stopped, Dell just recommends not having much I/O going on. My first step was to shutdown most of the VM's and make sure the SAN doesn't have a lot of I/O running on it.The environment that I'm working in on this one consists of 7 vSphere 4.1 hosts, with all of the VM's running off of this particular PS6000xv.






    Dell b2360dn firmware update 6.